미 국방규격 시험 및 관련 시험 : 2016년 3월 기준 당사가 지원할 수 있는 시험가능항목 입니다.
TEST
|
Method applied
|
Altitude
|
ASTM D4169‐14;
DEF STAN 00‐35, Part 3, Issue 4:2006:
Chapter 3‐09 Test CL9 ‐ Rapid and Explosive Decompression;
GR‐63‐CORE, Issue 1 Paragraph 4.1 and 5.1;
GR‐63‐CORE, Issue 2, 3 Paragraph 4.1.3 and 5.1.3;
IEC 60721‐4‐1:2001+A1:03 – Low air pressure;
IEC 60721‐4‐2:2001+A1:03 – Low air pressure;
IEC 60721‐4‐3:2001+A1:03 – Low air pressure;
IEC 60721‐4‐4:2001+A1:03 – Low air pressure;
IEC 60721‐4‐7:2001+A1:03 – Low air pressure;
IEC 60601‐1‐11;
IEC 60721‐3‐2;
JSS 55555:2000 Rev.3 Test Number 3;
ISO 10236 Part 9;
ISO 14708‐1:2000(E);
MIL‐B‐49430C (ER) Paragraph 4.8.7;
MIL‐B‐49458C (ER) Paragraph 4.7.7;
MIL‐PRF‐49471B (CR) Paragraph 4.7.7;
MIL‐STD‐202F Method 105C, Conditions A, B, C, and F;
MIL‐STD‐202G Method 105C, Conditions A, B, C, and F;
MIL‐STD‐810C Method 500.1, Procedures I and II;
MIL‐STD‐810D Method 500.2, Procedures I and II;
MIL‐STD‐810E Method 500.3, Procedures I and II;
MIL‐STD‐810F Method 500.4, Procedures I and II;
MIL‐STD‐810G Method 500.5 Procedures I, II, and III;
RTCA / DO‐160D, E, F, G Section 4, Paragraph 4.6.1, Category Ax, Bx, Cx, Dx, Ex, Fx;
UN Transport of Dangerous Goods, Test T.1
|
Temperature /
Altitude
|
Chapter 3‐11 Test CL11 ‐ High Temperature ‐ Low Pressure,
Chapter 3‐12 Test CL12 ‐ Low Temperature ‐ Low Pressure Test,
Chapter 3‐13 Test CL13 ‐ Low Temperature ‐ Low Pressure ‐ High Humidity;
MIL‐STD‐810C Method 504.1, Procedure I;
MIL‐STD‐810D Method 520.0, Procedure I;
MIL‐STD‐810E Method 520.1, Procedure I;
MIL‐STD‐810F Method 520.2, Procedure I;
MIL‐STD‐810G Method 520.3, Procedure I;
RTCA / DO‐160D, E, G Section 4
|
Bench Handling
|
MIL‐STD‐810C Method 516.2, Procedure V;
MIL‐STD‐810D Method 516.3, Procedure VI;
MIL‐STD‐810E Method 516.4, Procedure VI;
MIL‐STD‐810F Method 516.5, Procedure VI;
MIL‐STD‐810G Method 516.6, Procedure VI
|
Chemical processing
|
AMS-C-26074
AMS-P-81728
AMS-QQ-N-290
AMS-QQ-P-35
AMS-QQ-P-416
AMS-QQ-S-365
AMS 2404
AMS 2418
AMS 2422
AMS 2425
ASTM B 545
|
TEST
|
Method applied
|
Chemical processing
|
ASTM B733
MIL-C-14550
MIL-C-26074
MIL-C-5541
MIL-DTL-5541
MIL-G-45204
MIL-P-27418
MIL-P-81728
MIL-R-46085
MIL-STD-871
MIL-T-10727
|
Emissions
|
Agreement of VCCI V-3 (2013.04)
Agreement of VCCI V-3 (2014.04)
Agreement of VCCI V-3 (2015.04)
Agreement of VCCl V-3 (2012.04)
ANSI C63 .17 (I 998) and ANSI C63.4 (2003)
ANSI C63.10-2009
ANSI C63.10-2013
ANSI C63.17(2006) and ANSI C63.4 (2003)
ANSI C63.4 (2003) and Millimeter Wave Test Procedures
ANSI C63.4 (2003) with FCC Method - 47 CFR Part 11
ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart E
ANSI C63.4 (2009) with FCC Method - 47 Part 11.
ANSI C63.4 (2009) with FCC Method 47 CFR Part 15, Subpart B
ANSI C63.4 (2009) with FCC Method 47 CFR Part 15, Subpart C
ANSI C63.4 (2009) with FCC Method 47 CFR Part 15, Subpart E
ANSI C63.4 (2014) with FCC Method 47 CFR Part 15, Subpart B
AS/NZS CISPR 11 (2011)
AS/NZS CISPR 22 (2009)
AS/NZS CISPR 22 (2009) +Al (2010)
AS/NZS CISPR 22, 3rd Edition (2006)
AS/NZS CISPR 32:2013
BS EN 61326-2-2 (2006-06)
CISPR 12 (2007) + Al (2009)
CISPR 13, Edition 4.2 (2006-03)
CISPR 32, Ed. 1 (2012-01)
CNS 13438 (2006) (up to 6GHz)
CNS 13439 (20-06)
EN 12895 (2000)
EN 50270 (2006-1 l)
EN 55011 (2009) + Al (2010)
EN 55011; EN 55022 (2006);
EN 55012 (2007) +Al (2009)
EN 55013 (2001) + A l (2003) + A2(2006)
EN 55013:2013
EN 55014-1 (2006) + Al (2009) + A2 (2011)
EN 55015:2013
EN 55022 (1998) + Al(2000) + A2(2003)
EN 55022 (2006) + Al (2007)
EN 55022:2010
EN 55032 (20 12-05)
EN 55103-1 (2009)
EN 55103-1 (2009) +Al (2012)
EN 61000-3-2
|
TEST
|
Method applied
|
Emissions
|
EN 61000-3-2 (2006)
EN 61000-3-2 (2014)
EN 61000-3-2:2006 + Al:2009 + A2:2009
EN 61000-3-3
EN 61000-3-3, Ed. 2.0 (2008-09)
EN 61000-3-3:2013 (2013-08)
EN 61000-6-3 (2007) +Al (2011)
EN 61000-6-4 (2007)
EN 61000-6-4 (2007) + Al (2011)
EN 61326-2-1 (2006-05)
EN 61326-2-1 (2013)
EN 61326-2-2 (2013)
EN 61326-2-3 (2006-08)
EN 61326-2-3:2013
EN 61326-2-6 (2013)
EN 62040-2:2006
FCC CFR 47 Part 15B, Part 15C (using ANSI C63.4:2003) and Part 18 (using MP-5);
FCC KDB 789033 (June 6, 2014)
FCC KDB 905462 (May 15, 2015)
FCC OST/MP-5 (1986)
ICES-001 (2000-08)
ICES-001; ICES-003;
ICES-003 Issue 4 (2004)
ICES-003 Issue 5 (2012)
ICES-005 Issue 3 (May 2009)
ICES-006 Issue 2 (2009)
IEC 6 1000-3-3 Ed. 3.0 (2013-05)
IEC 60255-26 (2013-05)
IEC 61000-3-11, 1st edition
IEC 61000-3-12 Ed. 2.0 (2011)
IEC 61000-3-2 Ed. 3.2 (2009)
IEC 61000-3-2, Ed. 3.0 (2005) + Al (2008) +A2 (2009)
IEC 61000-3-2, Ed. 4.0 (2014-05)
IEC 61000-3-3 Ed. 2.0 (2008)
IEC 61000-6-4 (2006) +Al (2010)
IEC 61000·6·4 (2006·07)
IEC 61326-1 Ed. 2.0 (2012)
IEC/CISPR 11 Ed. 5 (2009-05)
IEC/CISPR 13, Ed. 5.0 (2009-06)
IEC/CISPR 14-1, Ed. 5.0 (2005) + Al (2008) + A2 (2011)
IEC/CISPR 22 (2008-09)
IEC/ClSPR 11Ed5 (2009-05) +Al(2010)
IEC/EN 61000-3-3 (1995) + Al (2001) + A2 (2005)
IEEE C63. I 7 (2013)
ISO 7637-2, Second edition (2004) + Al (2008)
KN 14-2 (Aru1ex 4) RRA Arulounce 2014-92 (Dec29,2014)
KN 22 (1 to 6 GHz);
KN 30 I 489-1 (Annex 8-1) w/ RRA Announce 2013-24 (6/17/2013)
KN 30 I 489-3 (Annex 8-8) w/ RRA Arulounce 2013-24 (6117/13)
KN 301-489-07 (Arulex 8-2); RRA Announce2012-21,(Jun 28,2012)
KN 301-489-07 (Arulex 8-2); RRA Announce2013-24,(Jun 17,2013)
KN 301-489-24 (Annex 8-4); RRA Announce2012-21 ,(Jun 28,2012)
KN 301-489-27(Arulex 8-14); RRA Announce2012-21 (Jun. 28,2012)
KN 301 489-17 (Annex 8-3) w/ RRA Announce 2013-24 (6/17/13)
KN 301 489-24 (Arulex 8-4) w/ RRA Announce 2013-24 (6/ 17/ 13)
|
TEST
|
Method applied
|
Emissions
|
KN 301 489-27 (Arulex 8-14) w/ RRA Announce 2013-24 (6/17/13)
KN 32:2013 (Annex 16)
KN 6 1000-6-4 (Annex 15) with RRA Anounce 2013-24 (6/ 17/2013)
KN 61000-3-1 1 (Annex 1-12); RRA 2014-37 (Sept. 23, 2014)
KN 61000-3-12 (Annex 1-11); RRA 2014-37 (Sept 23, 2014)
KN 61000-3-2 (Annex 1-11); RRA 2014-37 (Sept. 23, 2014)
KN 61000-3-3 (Annex 1-12); RRA 2014-37 (Sept. 23, 2014)
KN 61000-6-3 (2012-06)
KN 61000-6-3 (Annex 14) with RRA Announce 2013-24 (6/17/13)
KN 61000-6-4 (2012-06)
KN14-l (Annex 4) with RRA Announce 2013-24 (Jun. 17 2013)
KN22 (Annex 5) with RRA Announce 2012-2 1 (Jun. 28, 2012)
KN22 (Annex 5) with RRA Announce 2013-24 (June 17, 2013)
KNI 1 (Annex2) with RRA Announce 2012-21 (Jun. 28, 2012)
KNl 1(Annex2) with RRA Announce 2013-24 (June 17, 2013)
KNl4-l (Annex 4) with RRA Announce 2012-21 (Jun. 28, 2012)
lEC 61000-6-3 (2006-06)
lEC/CISPR 11, Ed. 4.1 (2004-06) + A2 (2006)
lEC/CISPR 22, Edition 5 (2005) + A1 (2005) + A2 (2006)
MIL-STD-461E/F, Methods RE101, RE102, CE101, CE102;
RRA 20 13-3 and 2013-24, June 17, 2013, Korean only
RRA 2014-8 and RRA 2014-37 (June 23, 2014)
RRA Announce 2012-21, K only (Jun. 28, 2012)
RRA Announce 2013-24, June 17, 2013;Korean onlyRRA Public Notification 2011-24, K only (Dec 23, 2011)
RTCA D0-160G
RTCA/D0-160F (2007)
RTCA/DO-160F, Section 21
SI 961 part 6.1
TCVN 7189:2009
TCVN 7189:2009 (CISPR 22:2006)
TEC 6 1000-6-3 (2006) +Al (2010)
VCCI V-3 (up to 6 GHz);
|
Immunity
|
CISPR 20 (2006) +Al (2013)
EN 50130-4 (1995) + Al(l998) & A2(2003)
EN 50130-4 (2011)
EN 55014-2:1997 +Al (2001) + A2 (2008)
EN 55024 (20 I 0)
EN 55103-2 (2009)
EN 60945 (2002) and JEC 60945 (2002)
EN 61000-4-3 (2006) +Al (2008) + A2 (2010)
EN 61000-6-1 (2007)
EN 61000-6-2 (2005)
EN 61326- 1:20 13
EN 61326-1(2006)
IEC 6 1326-2-6 Ed. 2.0 (2012)
IEC 61000-4-2, Ed. 2.0 (2008-12)
IEC 61000-4-3 Ed. 3.2 (2010)
IEC 61000-4-3, Ed. 3.0 (2006-02) + AI (2007) + A2 (20 I0)
IEC 61000-4-3, Ed. 3.1 (2008-04)
IEC 61000-4-4, Ed. 2.0 + Al (2010)IEC 61000-6-1, 2nd edition (2005-03)
IEC 61000-6-2, Edition 2.0 (2005-0 1)
IEC/CI SPR 24 ( 1997) and EN 55024 (1998) + A l(2001), A2(2003)
IEC/CISPR 14-2 Ed. 1.2 (2008)
IEC/EN 50121-4
IEC/EN 55024
|
TEST
|
Method applied
|
Immunity
|
IEC/EN 60601-1-2
IEC/EN 61000-4-10
IEC/EN 61000-4-12
IEC/EN 61000-4-13
IEC/EN 61000-4-16
IEC/EN 61000-4-9
IEC/EN 61326-1
IEC/EN/KN 61000-4-11
IEC/EN/KN 61000-4-2
IEC/EN/KN 61000-4-3
IEC/EN/KN 61000-4-4
IEC/EN/KN 61000-4-5
IEC/EN/KN 61000-4-6
IEC/EN/KN 61000-4-8
KN 60601-1-2 (Annex 2), RRA 2012-22, K only (Jun. 28, 2012)
KN 60601-1-2 (Annex 2), RRA 2013-25, K only (Jun. 17, 2013)
KN 61000-6-1(Annex11); RRA Announce 2012-22 (Jun 28, 2012)
KN 61000-6-1(Annex11); RRA Announce 2013-25 (Jun 17, 2013)
KN 61000-6-2 (Annex 14) w/ RRA Announce2013-25 (6/17/13)
KN 61000-6-2(Annex 14); RRA Announce 2012-22 (Jun.28,2012)
MIL-STD-461E/F, Methods CS101, CS106, CS114, CS115, CS116
MIL-STD-461E/F, Methods RS101, RS103
RTCA/DO-160F/160G, Section 15
RTCA/DO-160F/160G, Section 16
RTCA/DO-160F/160G, Section 17
RTCA/DO-160F/160G, Section 18
RTCA/DO-160F/160G, Section 19
RTCA/DO-160F/160G, Section 20
RTCA/DO-160F/160G, Section 22
RTCA/DO-160F/160G, Section 25
|
Mechanical Shock
|
ASTM D4169‐14, Schedule J‐ Concentrated Impact (Test Method D6344);
IEC 60068‐2‐75 – Hammer Tests;
IEC 60721‐4‐1:2001+A1:03 – Shock;
IEC 60721‐4‐2:2001+A1:03 – Shock;
IEC 60721‐4‐3:2001+A1:03 – Shock;
IEC 60721‐4‐4:2001+A1:03 – Shock;
IEC 60721‐4‐7:2001+A1:03 – Shock;
IEC 62262 (EN 62262, IK ratings) – Impact;
IEC 68‐2‐27, IEC 60068‐2‐27:Test Ea;
IEC 68‐2‐29, IEC 60068‐2‐29:Test Eb;
IS 10236 Part 10 ‐ Bump, IS 10236 Part 12 – Shock;
ISO 10651‐3 Lung Ventilators Medical Use Part 3 Section 4: Protection against
JEDEC Standard JESD22‐B104C;
JSS 55555:2000 Rev. 2 Test Number 4, 24;
mechanical hazards;
MIL‐B‐49430, Paragraph 4.8.5;
MIL‐B‐49458C (ER), Paragraph 4.7.5;
MIL‐PRF‐49471B (CR), Paragraph 3.9;
MIL‐STD‐1344A Method 2004.1, Conditions A, B, C, E, F, G, H and I;
MIL‐STD‐1344A Method 2004.1, Conditions A, B, C, E, F, G, H, and I;
MIL‐STD‐202F Method 213B, Conditions A, B, C, D, E, F, G,H, I, J, and K;
MIL‐STD‐810C Method 516.2, Procedures I, III, IV, and VI;
MIL‐STD‐810D Method 516.3, Procedures I, II, V, and VIII,
MIL‐STD‐810E Method 516.4, Procedures I, II, V, and VIII;
MIL‐STD‐810F Method 516.5, Procedures I, II, III, V, and VIII;
|
TEST
|
Method applied
|
Mechanical Shock
|
MIL‐STD‐810G Method 516.6 Procedures I, II, III, V, and VIII;
MIL‐STD‐883A Method 2002.1, Condition A;
MIL‐STD‐883E Method 2002.3, Condition A;
MIL‐STD‐883F Method 2002.4, Condition A;
MIL‐STD‐883G Method 2002.5, Condition A;
MIL‐STD‐883H Method 2002.6, Condition A;
MIL‐STD‐883J Method 2002.7, Condition A;
RTCA / DO‐160D Section 7, Paragraphs 7.3.1, 7.3.1.1, Crash Safety;
RTCA / DO‐160D, 160E Section 7, Paragraphs 7.2.1, 7.2.2, Operational;
RTCA / DO‐160E, 160F, 160G Section 7, Paragraphs 7.3.1, 7.3.2, Crash Safety;
UL‐1642 4ED Rev August 2006, Paragraph 14A
|
Salt Fog
|
ASTM B117, B117‐97, B117‐2003;
DEF STAN 00‐35, Part 3, Issue 4:2006 Chapter 4‐02 Test CN2;
GMW 14872;
IEC 68‐2‐11, Test Ka, Salt Fog, Corrigendum 1999;
IEC 68‐2‐52, IEC 60068‐5‐52, Test Kb Salt Fog, Cyclic;
IS 10236 Part 6;
ISO 9227;
JSS 55555:2000 Rev. 2 Test Number 9;
MIL‐C‐5541E Class: 1A and 3;
MIL‐C‐83733;
MIL‐STD‐1344A Method 1001.1, Conditions A, B, C and D;
MIL‐STD‐202F Method 101D, Conditions A and B;
MIL‐STD‐202G Method 101E, Conditions A and B;
MIL‐STD‐810C Method 509.1;
MIL‐STD‐810D Method 509.2;
MIL‐STD‐810E Method 509.3;
MIL‐STD‐810F Method 509.4;
MIL‐STD‐810G Method 509.5;
MIL‐STD‐883E Method 1009.8, Conditions A, B, C and F;
MIL‐STD‐883F Method 1009.8, Conditions A, B, C and F;
MIL‐STD‐883G Method 1009.8, Condition A, B, C and F;
MIL‐STD‐883H Method 1009.8, Condition A, B, C and F;
MIL‐STD‐883J Method 1009.8, Condition A, B, C and F;
RTCA / DO‐160D, E, F, G Section 14
|
Rain
|
BS EN 50130‐5:1999 Alarm Systems Part 5: Environmental Test Methods
DEF STAN 00‐35, Part 3, Issue 4:2006 Chapter 3‐27;
DEF STAN 00‐35, Part 3, Issue 4:2006 Chapter 3‐28;
IEC 60529‐2001 ‐02, Protection Against Water;
IEC 60529 IPX1 Vertically Dripping;
IEC 60529 IPX2 Dripping (150 tilted);
IEC 60529 IPX3 Spraying;
IEC 60529 IPX4 Splashing;
IEC 60529 IPX5 Jetting;
IEC 60529 IPX6 Powerful Jetting;
IEC 60529 IPX7 Immersion;
IEC 60529 IPX8 Immersion;
IEC 60529 IPX9 Resist Ingress of High Temperature (Steam)/High Pressure
IEC 60721‐4‐1:2001+A1:03 – Rain;
IEC 60721‐4‐2:2001+A1:03 – Rain;
IEC 60721‐4‐3:2001+A1:03 – Rain;
IEC 60721‐4‐4:2001+A1:03 – Rain;
IEC 60721‐4‐7:2001+A1:03 – Rain;
IEC 68‐2‐18, IEC 60068‐2‐18 Test Rb2;
|
TEST
|
Method applied
|
Rain
|
IS 10236 Part 14 – Driving Rain;
JSS 55555:2000 Rev.2 Test Number 11,12,16;
MIL‐STD‐108, Splash-proof;
MIL‐STD‐108E, Splash-proof Paragraph 4.9;
MIL‐STD‐810C Method 506.2, Procedures I and II;
MIL‐STD‐810D Method 506.3, Procedures I and II;
MIL‐STD‐810E Method 506.4, Procedures I and III;
MIL‐STD‐810F Method 506.5, Procedures I and III;
MIL‐STD‐810G Method 506.6, Procedures I and III;
RTCA / DO‐160D,E,F,G Section 10;Water;
|
Sand & Dust
|
DEF STAN 00‐35, Part 3, Issue 4:2006 Chapter 3‐25 Test CL25;
IEC 60529‐2001 COR 1 2003, Degrees of Protection provided by Enclosures (IP Code) Degrees of protection (IP‐Code), IP5X,6X;
IS 10236 Part 13;
JSS 55555:2000 Rev.2 Test Number 14;
MIL‐STD‐810 C, D, E, F, G, Method 510, Procedures I, II and III;
RTCA / DO‐160 C,D,E,F,G, Section 12, Procedure II
|
Solar Radiation
(Sunshine)
|
ASTM G154‐12a;
BS EN 50130‐5:11;
BS EN 50130‐5:1999 Alarm Systems Part 5 : Environmental Test Methods;
MIL‐STD‐810C, D, E, F, G Method 505.1, Procedure I;
MIL‐STD‐810C, D, E, F, G Method 505.1, Procedure II;
IEC 60068‐2‐5:75; Part 2‐5: Tests ‐ Test Sa;
IEC 60068‐2‐5:10;
IEC 60721‐4‐1:2001+A1:03 – Solar Radiation;
IEC 60721‐4‐2:2001+A1:03 – Solar Radiation;
IEC 60721‐4‐3:2001+A1:03 – Solar Radiation;
IEC 60721‐4‐4:2001+A1:03 – Solar Radiation;
IEC 60721‐4‐7:2001+A1:03 – Solar Radiation;
IS 10236 Part 16;
JSS 55555:2000 Rev.2 Test Number 25
|
Temperature
|
EIA/JEDEC Standard EIA/JESD22‐A104‐B;
EN 50130‐5 Section 8 Dry Heat (Operational);
EN 50130‐5:1999 Section 8 Dry Heat (Operational);
EN 50130‐5:1999 Section 9 Dry Heat (Endurance);
EN 50130‐5:1999 Section 10 Cold (Operational);
EN 50130‐5:1999 Section 11 Temperature Change (Operational);
ETSI 300‐019‐2‐1,2,3,4,5,6,7,8;
GR‐63‐CORE, Paragraph 5.1.1.1, Low Temperature;
GR‐63‐CORE, Paragraph 5.1.1.2, High Temperature;
GR‐1221‐CORE, Paragraph 6.2.4, High Temperature;
GR‐1221‐CORE, Paragraph 6.2.6, Low Temperature;
GR‐1221‐CORE, Paragraph 6.2.7, Thermal Shock;
|
TEST
|
Method applied
|
Temperature
|
IEC 68‐2‐1, IEC 60068‐2‐1, Test Aa, Ab, Ac, and Ad, Low Temperature;
IEC 68‐2‐2, IEC 60068‐2‐2, Test Ba, Bb, Bc and Bd, High Temperature;
IEC 68‐2‐14, IEC 60068‐2‐14, Test Na, Nb and Nc, Temperature Cycling;
IEC 60721‐4‐1:2001+A1:03 – Low Temperature;
IEC 60721‐4‐1:2001+A1:03 – High Temperature;
IEC 60721‐4‐1:2001+A1:03 – Temperature cycle;
IEC 60721‐4‐2:2001+A1:03 – Low Temperature;
IEC 60721‐4‐2:2001+A1:03 – High Temperature;
IEC 60721‐4‐2:2001+A1:03 – Temperature cycle;
IEC 60721‐4‐3:2001+A1:03 – Low Temperature;
IEC 60721‐4‐3:2001+A1:03 – High Temperature;
IEC 60721‐4‐3:2001+A1:03 – Temperature cycle;
IEC 60721‐4‐4:2001+A1:03 – Low Temperature;
IEC 60721‐4‐4:2001+A1:03 – High Temperature;
IEC 60721‐4‐4:2001+A1:03 – Temperature cycle;
IEC 60721‐4‐7:2001+A1:03 – Low Temperature;
IEC 60721‐4‐7:2001+A1:03 – High Temperature;
IEC 60721‐4‐7:2001+A1:03 – Temperature cycle;
IS 10236 Part 2 – Dry Heat;
IS10236 Part 3 – Cold;
IS 10236 Part 8 – Thermal Shock;
ISO 14708‐1:200 (E);
JSS 55555:2000 Rev. 2 Test Number 13, 20, 22;
MIL‐STD‐202F Method 107D, Conditions A, A‐1, A‐2, A‐3, B, B‐1, B‐2, B‐3, F, F‐1, F‐2, and F‐3, Thermal Shock;
MIL‐STD‐202G Method 107G, Conditions A, A‐1, A‐2, A‐3, B, B‐1, B‐2, B‐3, F, F‐1, F‐2, and F‐3, Thermal Shock;
MIL‐STD‐202F, G Method 108A, High Temperature;
MIL‐STD‐810C Method 501.1, Procedure I, High Temperature;
MIL‐STD‐810C Method 501.1, Procedure II, Temperature Cycling;
MIL‐STD‐810C Method 502.1, Procedure I, II, III Low Temperature;
MIL‐STD‐810C Method 503.1, Procedure I, Thermal Shock;
MIL‐STD‐810D Method 501.2, Procedure I, II High Temperature;
MIL‐STD‐810D Method 502.2, Procedure I, II, III Low Temperature;
MIL‐STD‐810D Method 503.2, Procedure I, Thermal Shock;
MIL‐STD‐810E Method 501.3, Procedure I, II High Temperature;
MIL‐STD‐810E Method 502.3, Procedure I, II Low Temperature;
MIL‐STD‐810E Method 502.3, Procedure III, Low Temperature;
MIL‐STD‐810E Method 503.3, Procedure I, Thermal Shock;
MIL‐STD‐810F Method 501.4, Procedure I, II High Temperature;
MIL‐STD‐810F Method 502.4, Procedure I, II, III Low Temperature;
MIL‐STD‐810F Method 503.4, Procedure I, II Thermal Shock;
MIL‐STD‐810G Method 503.5, Procedure I, II Thermal Shock;
MIL‐STD‐810G Method 501.5, Procedure I, II High Temperature;
MIL‐STD‐810G Method 502.5, Procedure I, II, III Low Temperature;
MIL‐STD‐883E, F, G, H Method 1010.7, Condition A, B, C, and F, Thermal
Shock;
RTCA / DO‐160D, E, F, G Section 4 and 5;
TIA/EIA 455‐4C, High Temperature
|
Temperature and Humidity
|
BS EN 50130‐5:1999 Alarm Systems Part 5: Environmental Test Methods;
DEF STAN 00‐35, Part 3, Issue 4:2006;
EIA/JEDEC Standard EIA/JESD22‐A101‐B;
EN 50130‐5:1999 Section 12 Damp Heat, Steady State (Operational);
EN 50130‐5:1999 Section 13 Damp Heat (Endurance);
|
TEST
|
Method applied
|
Temperature and Humidity
|
EN 50130‐5:1999 Section 14 Damp Heat Cycling (Operational);
EN 50130‐5:1999 Section 15 Damp Heat Cycling (Endurance);
GM 9123P;
GR‐63‐CORE, Issue 1, Paragraph 5.1.1.3, Humidity;
GR‐63‐CORE, Issue 1, 2 and 3, Paragraph 5.1.2, Humidity;
GR‐1221‐CORE, Paragraph 6.2.5 and 6.2.8, Humidity;
IEC 68‐2‐3, Test Ca, Humidity replaced by IEC 60068‐2‐78;
IEC 68‐2‐30, IEC 60068‐2‐30, 3ed 2005, Test Db, Humidity;
IEC 68‐2‐38 led 1974,Test Z/AD, Humidity;
IEC 60068‐2‐56, Test Cb, Humidity superseded by IEC 680068‐2‐78:2001;
IEC 60721‐4‐1:2001+A1:03 – Humidity/Damp Heat;
IEC 60721‐4‐2:2001+A1:03 – Humidity/Damp Heat;
IEC 60721‐4‐3:2001+A1:03 – Humidity/Damp Heat;
IEC 60721‐4‐4:2001+A1:03 – Humidity/Damp Heat;
IEC 60721‐4‐7:2001+A1:03 – Humidity/Damp Heat;
IS 10236 Part 4 – Damp Heat;
IS 10236 Part 5 – Damp Hear (Cyclic);
ISTA 1A‐ 2014, ISTA 2A‐2011, ISTA 3A‐2008;
JSS 55555:2000 Rev. 2 Test Number 10, 27;
MIL‐STD‐202F Method 103B, Conditions A, B, C, and D, Humidity;
MIL‐STD‐202F Method 106E, Humidity;
MIL‐STD‐202G Method 103B, Conditions A, B, C, and D, Humidity;
MIL‐STD‐202G Method 106G, Humidity;
MIL‐STD‐810C Method 507.1, Procedures I, II, III, IV, and VI;
MIL‐STD‐810D Method 507.2, Procedures I, II, and III;
MIL‐STD‐810E Method 507.3, Procedures I, II, and III;
MIL‐STD‐810F Method 507.4, Procedure I;
MIL‐STD‐810G Method 507.5 Procedures I, and II;
MIL‐STD‐883E Method 1004.7;
MIL‐STD‐883F Method 1004.7;
MIL‐STD‐883G Method 1004.7;
MIL‐STD‐883H Method 1004.7;
MIL‐STD‐883J Method 1004.7;
MIL‐STD‐1344A Method 1002.2, Type I, Conditions A, B, C, and D;
MIL‐STD‐1344A Method 1002.2, Type II, and III;
RTCA / DO‐160C,D,E,F,G Section 6;
TIA/EIA 455‐5C, Method A, Conditions A, B, C, D and E, Humidity;
TIA/EIA 455‐5C, Method B and C, Humidity;
|
Vibration
|
ASTM D999, ASTM D999‐96, D999‐2001 Method Al, B, C, Sine Vibration;
ASTM D4169‐14;
ASTM D4728, ASTM D4728‐95, D4728‐2006 RandomVibration;
BRB/LU Ltd /RIA SPECIFICATION No 20:1988 (Testing for Railway Vehicles);
DET NORSKE VERITAS (DNV) STANDARD FOR CERTIFICATION NO. 2.4
: ENVIRONMENTAL TEST SPECIFICATIONFOR INSTRUMENTATION
ANDAUTOMATION EQUIPMENT (April 2006);
GR‐63‐CORE, Paragraph 5.4.2, Sine Vibration;
GR‐63‐CORE, Paragraph 5.4.3, Sine Vibration;
GR‐1221‐CORE, Paragraph 6.2.2, Sine Vibration;
General Motors Engineering Standards GM 9123P;
General Motors Engineering Standards GM 3155;
IEC 68‐2‐6, IEC 60068‐2‐6, Test Fc, Sine Vibration;
IEC 68‐2‐34:73 AMD 1 83, Test Fd, Random Vibration;
|
TEST
|
Method applied
|
Vibration
|
IEC 68‐2‐36, Test Fdb, Random vibration superseded by IEC 60068‐2‐64;
IEC 68‐2‐64 1993 COR 1 1993, Test Fh, Random Vibration;
IEC 60601‐1‐11;
IEC 60721‐4‐1:2001+A1:03 – Sine Vibration;
IEC 60721‐4‐2:2001+A1:03 – Random Vibration;
IEC 60721‐4‐2:2001+A1:03 – Sine Vibration;
IEC 60721‐4‐3:2001+A1:03 – Sine Vibration;
IEC 60721‐4‐4:2001+A1:03 – Sine Vibration;
IEC 60721‐4‐7:2001+A1:03 – Random Vibration;
IEC 60721‐4‐7:2001+A1:03 – Sine Vibration;
IEC 60721‐3‐2;
IS 10236 Part 11;
ISTA 1A‐2014, ISTA 2A‐2011, ISTA 3A‐2008;
JIS E 3014: 1999 Part of Railway signal – Vibration Test Methods;
JSS 55555:2000 Rev. 2 Test Number 4, 28;
MIL‐B‐49430, Paragraph 4.8.6, Sine Vibration;
MIL‐B‐49458C (ER), Paragraph 4.8.6, Sine Vibration;
MIL‐DLT‐62547C(AT);
MIL‐PRF‐49471B (CR), Paragraph 4.7.6;
MIL‐STD‐202F Method 201A, Sine Vibration;
MIL‐STD‐202F Method 204D, Test Conditions A, B, C, D, E, F, G, H, Sine Vibration;
MIL‐STD‐202F Method 214 Condition I, Test Conditions A, B, C, D, E, F, G, H, J, K, Random Vibration;
MIL‐STD‐202F Method 214 Condition II, Test Conditions A, B, C, D, E, F, G, H, J, K, Random Vibration;
MIL‐STD‐202G Method 201 A, Sine Vibration;
MIL‐STD‐202G Method 204D, Test Conditions A, B, C, D, E, F, G, H, Sine Vibration;
MIL‐STD‐202G Method 214 Condition I, Test Conditions A, B, C, D, E, F, G, H, J, K, Random Vibration;
MIL‐STD‐202G Method 214 Condition II, Test Conditions A, B, C, D, E, F, G, H, J, K, Random Vibration;
MIL‐STD 167 ‐1A:05 ‐ Vibrations of Shipboard Equipment;
MIL‐STD‐810C Method 514.2, Procedure I, Curve AR‐L, Sine Vibration;
MIL‐STD‐810C Method 514.2, Procedure 1, Curve B, Sine Vibration;
MIL‐STD‐810C Method 514.2, Procedure 1, Curve M, Sine Vibration;
MIL‐STD‐810C Method 514.2, Procedure IA, Figure 514.2‐2A, Random Vibration;
MIL‐STD‐810C Method 514.2, Procedure IIA, Figure 514.2‐4, Random Vibration;
MIL‐STD‐810C Method 514.2, Procedure IIB, Figure 514.2‐4A, Random Vibration;
MIL‐STD‐810C Method 514.2, Procedure V, VI, VII,
Figure 514.2‐4A, Sine & Random Vibration;
MIL‐STD‐810C Method 514.2, Procedure VIII, Curve V, Sine Vibration;
MIL‐STD‐810C Method 514.2, Procedure VIII, Curve W, Sine Vibration;
MIL‐STD‐810C Method 514.2, Procedure VIII, Curve Y, Sine Vibration;
MIL‐STD‐810D Method 514.3, Category 1, Procedure I, Random Vibration;
EIA/JEDEC STANDEARD EIA/JESD22 –B103‐B;
MIL‐STD‐810D Method 514.3, Category 10, Procedure 1, Sine & Random Vibration;
MIL‐STD‐810D Method 514.3, Category 4, 5, 6, 7B, 7C, 8, 9, Procedure I, Random Vibration;
|
TEST
|
Method applied
|
Vibration
|
MIL‐STD‐810D Method 514.3, Category 7A, Procedure IV, Random Vibration;
MIL‐STD‐810D Method 519.3, Random Vibration;
MIL‐STD‐810E Method 514.4, Category 1, 4, 5, 6, 7B, 7C, 8, 9, Procedure I, Random Vibration;
MIL‐STD‐8 I0E Method 514.4, Category 10, Procedure 1, Sine & Random
Vibration;
MIL‐STD‐810E Method 514.4, Category 7A, Procedure IV, Random Vibration;
MIL‐STD‐8 1OE Method 519.4, Gunfire Vibration;
MIL‐STD‐810E Method 521.1;
MIL‐STD‐810F Method 514.5 Category 1, 2, 3, 4, 7, 8, 9, 10, 11, 12, 13, 14, 16, 17, 18, 19, 20, 21, 22, 23, 25, Procedure I, Random Vibration;
MIL‐STD‐810F Method 514.5, Category 15, 17, 18, 19, Procedure IV, Random Vibration;
MIL‐STD‐810F Method 514.5, Category 20, Procedure III, Random Vibration;
MIL‐STD‐8 10F Method 514.5, Category 24, Procedure 1, Sine Vibration;
MIL‐STD‐810F Method 519.5, Gunfire Vibration;
MIL‐STD‐810F Method 521.2;
MIL‐STD‐810F Method 528, Shipboard Equipment;
MIL‐STD‐810G Method 514.6, Category 1, 2, 3, 4, 7, 8, 9, 11, 12, 13, 14, 16, 17, 18, 19, 20, 221, 22, 23, 24, 25, Procedure I, Random Vibration;
MIL‐STD‐810G Method 514.6, Category 15, 17, 18, 19, Procedure IV, Random Vibration;
MIL‐STD‐810G Method 514.6, Category 20, Procedure III, Random Vibration;
MIL‐STD‐810G Method 519.6, Gunfire Vibration;
MIL‐STD‐810G Method 521.3;
MIL‐STD‐883E, F, G, H, J Method 2005.2, Test Conditions A, B, C, Sine Vibration;
MIL‐STD‐883E, F, G, H, J Method 2006.1, Sine Vibration;
MIL‐STD‐883E, F, G, H, J Method 2007.2, Test Conditions A, B, C, Sine Vibration;
MIL‐STD‐883E, F, G, H, J Method 2026, Condition 1, Test Conditions A, B, C, E, F, G, H, J,K, Random Vibration;
MIL‐STD‐883E, F, G, H, J Method 2026, Condition 11, Test Conditions A, B, C, E, F, 0, H, J, K, Random Vibration;
MIL‐STD‐ I 344A Method 1015, Condition B (Group III) Sine Vibration;
MIL‐STD‐ I 344A Method 2005.1, Conditions I, II, III, IV, V (A, B, C, D, E, F, G,H, J, K), VI (A, B, C, D, E, F, G, H, J, K);
RTCA / DO‐160D Section 8;
RTCA / DO‐160E Section 8;
RTCA / DO‐160F Section 8;
RTCA / DO‐160G Section 8;
TIA/EIA 455‐1 IB, TIA/EIA 455‐11C, Condition I, Sine Vibration;
TIA/EIA 455‐1113, TIA/EIA 455‐11C, Condition 11, Sine Vibration;
TIA/EIA 455‐1113, TIA/EIA 455‐11C, Condition III, Sine Vibration;
TIA/EIA 455‐11B, TIA/EIA 455‐11C, Condition IV, Sine Vibration;
TIA/EIA 455‐1113, TIA/EIA 455‐11C, Condition IV, Sine Vibration;
TIA/EIA 455‐1113, TIA/EIA 455‐11C, Condition VI, Random Vibration;
TIA/EIA 455‐1 IB, TIA/EIA 455‐11C, Condition VII, Random Vibration;
TIA/EIA 455‐1 I C, TIAIEIA 455‐11C, Condition I, Sine Vibration;
TIA/EIA 455‐11C, TIA/EIA 455‐11C, Condition II, Sine Vibration;
|
TEST
|
Method applied
|
Vibration
|
TIA/EIA 455‐1 IC, TIA/EIA 455‐11C, Condition III, Sine Vibration;
TIA/EIA 455‐11 C, TIA/EIA 455‐11C, Condition IV, Sine Vibration;
TIA/EIA 455‐11C, TIA/EIA 455‐11C, Condition IV, Sine Vibration;
TIA/EIA 455‐1 1C, TIA/EIA 455‐11C, Condition VI, Random Vibration;
TIA/EIA 455‐11C, TIA/EIA 455‐11C, Condition VII, Random Vibration;
QM‐333 Paragraph 12.0, Category A, B, C, D, Sine Vibration;
UL‐1642, Paragraph 15, Sine Vibration;
UN Transport of Dangerous Goods, Test T.2, Sine Vibration;
ISO 10651‐3 Lung Ventilators Medical Use Part 3;
ISO 14708‐1:200 (E), Section 4: Protection against mechanical hazards;
BS EN 50155:2007;
BS EN 61373:1999;
DEF‐STD 00‐35 part 3;
DEF‐STD 00‐35 part 5;
ETSI 300‐019‐2‐1, 2, 3, 4, 5, 6, 7, 8;
NATO AECTP‐400 Edition 3;
BMW Group GS95003‐1;
ASTM D999, Method A1, B, C, Sine Vibration;
ASTM D999, ASTM D999‐96, D999‐2001 (Method A1, B, C, Sine Vibration);
ASTM D4728, Random Vibration;
ASTM D4728, ASTM D4728‐95, D4728‐2006 Random Vibration;
EN 50130 Section 22,23 Vibration, Sinusoidal;
EN 50130:1999 Section 22 Vibration, Sinusoidal (Operational);
EN 50130:1999 Section 23 Vibration, Sinusoidal (Endurance);
BS EN 50130‐5:1999 Alarm Systems Part 5 : Environmental Test methods
|
*참고자료: http://blogattach.naver.com/59cc45f5e7b5bd614faec3fac022582284d32cca7c/20160328_51_blogfile/apnetwork7_1459160408765_OCz73g_pdf/Scope+of+test-by-anycerti.com.pdf?type=attachment
*출처: www.anycerti.com
[J]